Module Huawei ES1D2SRUH000
15000 $
Interface modules (line cards) Huawei depending on the type and functions are divided into the following types: Main Processing Unit (MPU) - Main Processor, Switch Fabric Unit (SFU) - Switching block, Centralized Monitoring Unit (CMU) - Centralized monitoring unit, Line Processing Unit (LPU, also called interface card or line card) - Linear Processor (LPU, also called interface card or line card, and others.
These modules add functionality to existing modular routers or switches. Each Huawei series or sub-series has its own interface modules, line cards, processor and network devices.
These modules can expand the functionality at high speeds, such as 100GE, or increase the performance of a router or switch. Huawei.
For convenience and understanding of the module, you can use this table, by decoding part numbers Huawei. For example, a part number of this kind:
decrypted as follows according to this table: module Huawei CE series, with 24 ports 40GE QSFP
Identifier |
Meaning |
Description |
A |
Brand |
It is fixed as CE, representing CloudEngine. |
B |
Line card type |
|
C |
Number of interfaces on the card |
For a line card with different types of interfaces, this field stands for the number of downlink interfaces. It has two digits. The first digit is 0 if the card has fewer than 10 interfaces. |
D |
Interface rate |
|
E |
Interface type |
|
F |
Line card specifications |
|
Specifications of the interface module Huawei ES1D2SRUH000:
ES1D2SRUH000 Specification |
|
Basic functions |
The ES1D2SRUH000 is the system control and management unit for the S7712 and S7706. It integrates the main control unit, switching unit, and system maintenance unit. |
Distributed forwarding |
Performs concurrent data forwarding using a distributed data plane. |
Memory |
4 GB |
Flash |
64 MB |
eUSB card |
2 GB The system configuration data, startup files, system software package, and system logs are saved in the eUSB card by default. |
CSS |
The ES1D2SRUH000 can have the ES1D2VS04000 installed to support the CSS function in V200R009C00 and later versions. |
OAM |
The ES1D2SRUH000 can have ES0D00FSUA00 installed to provide enhanced services such as Operation, Administration and Maintenance (OAM) and Bidirectional Forwarding Detection (BFD). 802.1ag: identifies, detects, and sends continuity check (CC) packets. Multiprotocol Label Switching (MPLS OAM): identifies, detects, and sends MPLS OAM packets. OAM UNCFG_MEP. |
Redundancy backup |
Supported Main control board is mandatory for switches. Each switch must be configured with one or two main control boards. When one main control board is configured for a switch, the main control board can be installed in either main control board slot of the switch. When two main control boards are configured, the two main control boards work in hot standby mode to improve reliability of the switch. The active and standby main control boards monitor the status of each other. If the active main control board fails, the standby main control board automatically becomes active to ensure uninterrupted services. |
Hot swap |
Supported Before removing the active ES1D2SRUH000, perform an active/standby switchover. |
Physical specifications |
Dimensions (W x D x H): 394.7 mm x 426.8 mm x 35.1 mm (15.5 in. x 16.8 in. x 1.4 in.) Reserved subcard slot: 243.7 mm x 170.0 mm x 35.1 mm (15.5 in. x 6.7 in. x 1.4 in.) Weight: 3.46 kg (7.63 lb) Maximum power consumption: 183 W (including subcards) |
Environment parameters |
Operating temperature: 0°C to 45°C (32°F to 113°F) Operating relative humidity: 5% RH to 95% RH (noncondensing) Storage temperature: -40°C to +70°C (-40°F to +158°F) Storage relative humidity: 5% RH to 95% RH (noncondensing) |
EMC compliance |
CISPR22 Class A CISPR24 EN55022 Class A EN50024 ETSI EN 300 386 Class A CFR 47 FCC Part 15 Class A ICES 003 Class A AS/NZS CISPR22 Class A VCCI Class A IEC61000-6-2 IEC61000-6-4 IEC61000-4-2 ITU-T K 20 ITU-T K 21 ITU-T K 44 CNS13438 CLASS A KN 22 CLASS A |
Environmental standards compliance |
RoHS REACH WEEE |
Safety standards compliance |
IEC 60950-1 EN 60950-1 UL 60950-1 CSA C22.2 No 60950-1 AS/NZS 60950.1 BS EN 60950-1 |
condition | new |
---|
Log In