Memory
|
Default and maximum DRAM
|
4 GB
|
Default and maximum Flash memory
|
8 GB (physical) / 4 GB (usable)
|
Ingress protection rating
|
IP30
|
Physical characteristics
|
Physical dimensions (H x W x D)
В
Chassis
В
Expansion Module
|
В
В
В
2.36 in. x 5.22 in. x 4.92 in. (60 x 132.5 x 124.9 mm)
В
1.3 in. x 5.2 in. x 4.9 in. (33 x 132 x 124 mm)
|
Weight
В
Chassis
В
Expansion Module
IRM-1100-SPMI:
IRM-1100-SP:
|
В
2.25 lbs (1.02 kg)
В
В
В
В
1.65 lbs (0.75 kg)
1.45 lbs (0.66 kg)
|
Mounting options
|
Panel, wall, and din rail (vertical and horizontal) mount
|
Power specifications
|
Nominal voltage: 12V to 48V DC
Minimum and maximum input voltage: 9.6-60V DC
Maximum and minimum input current: 1.24A (9.6V DC) and 0.26A (60V DC)
|
Power consumption
|
At idle: 6.6W
Typical: 9.8W
Maximum: 12W
Additional 10W (typical) with expansion module and 2ndВ cellular
|
Interfaces on the base platform
|
Console
|
Mini type-B USB
|
WAN interfaces
|
-В В Combo 10/100/1000 Gigabit Ethernet port (RJ45 and SFP) on the base platform
-В В An additional 10/100/1000 Gigabit Ethernet SFP on the expansion module. Refer to Table 8 for supported SFPs
-В В LTE: Modular with options for single and dual active LTE and LTE-Advanced
|
LAN interfaces
|
-В В Four 10/100BASE-T Fast Ethernet ports
|
Input and output
|
-В В ALARM input port
|
LEDs
|
-В В System OK
-В В Link for Ethernet WAN ports
-В В VPN
-В В Tricolor user-configurable LED
-В В ALARM
|
Serial interface
|
-В В Isolated RS-232 RJ45 DTE port
-В В Support for asynchronous mode with speeds up to 115,200 baud
|
Serial protocols
|
SCADA, DNP3, T101-104, Raw Socket TCP, and UDP
|
Environmental characteristics
|
Environmental operating temperature range
|
–40 to 140°F (–40 to 60°C) in a sealed NEMA cabinet with no airflow
–40 to 158°F (–40 to 70°C) in a vented cabinet with 40 Linear Feet per Minute (LFM) of air
–40 to 167°F (–40 to 75°C) in a forced air enclosure with 200 LFM of air
Type tested at 85В°C for 16 hours
|
Operating altitude
|
40В°C up to 13,800 ft (operating) per IEC 68-2-41
|
Non-operating shock and vibration
|
-В В 50-60G (3.76 m/s minimum)
-В В 3-500Hz at 1.12 GRMS (BP at 10 and 100 Hz)
|
Standard safety certifications
|
-В В UL 60950-1, 2В ndВ edition
-В В CAN/CSA C22.2 No. 60950-1, 2В ndВ edition
-В В EN 60950-1, 2В ndВ edition
-В В CB to IEC 60950-1, 2В ndВ edition with all group differences and national deviations
|
Hazardous locations standards
|
-В В ANSI/ISA 12.12.01 (Class 1, Div 2 A-D)
-В В CSA 213 (Class 1, Div 2 A-D)
-В В IEC 60079-0 and -15 IECEx test report (Class I, Zone 2, gas groups IIC)
-В В EN 60079-0 and -15 ATEX certification (Class I, Zone 2, gas groups IIC)
|
Industry standards
|
-В В IEC 61850-3
-В В IEEE 1613
|
EMC emissions CLASS A
|
-В В 47 CFR Part 15 B
-В В EN 55032:2015
-В В CISPR 32 Edition 2
-В В CNS13438: 2006
-В В EN 300 386 V1.6.1
-В В ICES-003 Issue 6: 2016
-В В KN 32: 2015
-В В TCVN 7189: 2009
-В В V-2/2015.04
-В В V-3/2015.04
-В В AS/NZ CISPR32
|
EMC immunity
|
-В В EN 61000-4-2, 3, 4, 5, 6, 8, 9, 16, 17, 18, and 29
-В В CISPR24: 2010 + A1: 2015
-В В EN 300 386 V1.6.1
-В В EN 55024: 2010 + A1: 2015В
-В В EN 55035:2017
-В В KN35: 2015
-В В TCVN 7317:2003
-В В QCVN 18:2014
|
Log In