Memory
|
В
|
Default and maximum DRAM
|
1 GB
|
Default and maximum flash memory
|
4 GB
|
IP rating
|
IP30
|
Physical characteristics
|
В
|
Physical dimensions (H x W x D)
|
1.84” x 5.07” x 4.37” (46.74 x 128.78 x 110.99 mm)
|
Weight
|
1 lb 5 oz. (0.6 kg)
|
Mounting options
|
Panel, wall, and DIN rail (vertical and horizontal) mount
|
Power consumption
|
At idle: 4.5W
Typical: 6.7W
Maximum: 10W
|
Interface support
|
Console
|
Mini type-B USB
|
WAN interfaces
|
WWAN with multimode 4G LTE, 3.7G, 3.5G, 3G, and 2G speeds; IR807G-LTE-VZ-K9 does not support 3G and 2G. IR807G-LTE-NA-K9 does not support 2G
|
LAN and WAN interfaces
|
Two 10/100BASE-T fast Ethernet ports
|
LEDs
|
-В В В System OK
-В В В WWAN
-В В В Link for Ethernet WAN ports
-В В В GPS
-В В В RSSI
-В В В VPN
-В В В User-configurable LED
-В В В SIM presence
-В В В ALARM
|
Serial interface
|
-В В В 2 isolated RS-232 ports
-В В В Support for asynchronous mode with speed up to 115,200 baud
|
Serial protocol support
|
SCADA, DNP3, T101-104, Raw Socket TCP and UDP, and SLIP
|
Diagnostics
|
Mini type-B USB for remote cellular WAN diagnostics and monitoring
|
Environmental characteristics
|
Environmental operating temperature range
|
–40 to 140°F (–40 to 60°C) in a sealed NEMA cabinet with no airflow
–40 to 158°F (–40 to 70°C) in a vented cabinet with 40 linear feet per minute (LFM) of air
–40 to 167°F (–40 to 75°C) in a forced air enclosure with 200 LFM of air
Type tested at 85В°C for 16 hours
|
Operating altitude
|
50?C up to 5000 ft (above 5000 ft derate maximum operating temperature 1.50В°C per 1000 ft)
Maximum altitude: 10,000 ft
|
Standard safety certifications
|
-В В В UL 60950-1, 2В ndВ edition
-В В В CAN/CSA C22.2 No. 60950-1, 2В ndВ edition
-В В В EN 60950-1, 2В ndВ edition
-В В В CB to IEC 60950-1, 2В ndВ edition with all group differences and national deviations
|
Hazardous locations standards
|
-В В В ANSI/ISA 12.12.01 (Class 1, Div 2 A-D)
-В В В CSA 213 (Class 1, Div 2 A-D)
-В В В IEC 60079-0 and -15 IECEx test report (Class I, Zone 2, gas groups IIC)
-В В В EN 60079-0 and -15 ATEX certification (Class I, Zone 2, gas groups IIC)
|
Industry standards
|
-В В В IEC 61850-3
-В В В IEEE 1613
|
EMC emissions
|
FCC 47 CFR Part 15 Subpart C Class A
EN 55032/CISPR 32 Class A, EN 55022 Class A
CISPR 11 Class A, ICES 003 Class A, CNS 13438 Class A
EN 300 386
|
EMC immunity
|
CISPR 35, EN 55024
EN 61000-4-2, 3, 4, 5, 6, 8, 9, 16, 17, 18, and 29
|
Radio cellular
|
EN 301 908 -1, 2, and 13
EN 301 511
FCC 47 CFR Part 22
FCC 47 CFR Part 15 Subpart C
FCC 47 CFR Part 2 MPE
RSS 102/247
|
Power specifications
|
Minimum and maximum voltage: 9.6 to 60V DC input
Maximum and minimum current: 1.04A (9.6V DC) and 0.17A (60V DC)
|