Router Huawei NetEngine 8000E F1A-C
SKU
NetEngine 8000E F1A-C
EAN:
21461
Condition:
new
Stock:
available on order
Lead time:
25-35 days
Huawei NetEngine 8000E F1A-C Fixed-configuration (does not support flexible cards)
Category: Huawei Router
Routers Huawei NetEngine used in individual, private corporate networks of different sizes. The height of the apparatus varies from 2 U to 4 U, And the depth of the units at the same time is everything 220 mm, This feature of switches allows you to significantly save space in the hardware room..
Routers function Huawei NetEngine in a very wide range of temperatures that varies within - 40 up to + 60 degrees, which allows operation in complex, harsh environments.
Technical features:
- Unique chips of their own development Huawei Provide increased information transmission speeds
- «Hard» IP The channel improves the quality of services of a separate IP line
- Unique technologies IP FPM and hardware function BFD allow you to quickly and most importantly determine the fault and its character
- Architecture SDN, Performs a balanced distribution of traffic, increases the efficiency of using the bandwidth
| Specification | Detail |
|---|---|
| Product Name | Huawei NetEngine 8000E F1A-C |
| Switching Capacity | 2.4 Tbps |
| Forwarding Performance | 453 Mpps |
| Maximum Board Capability | Fixed-configuration (does not support flexible cards) |
| Capacity Density (Gbps per U) | 1200 Gbps / U |
| Main Control Board / MPU | Fixed configuration |
| SFU (Switch Fabric Unit) Redundancy | Fixed configuration |
| Line Card / Slot Count | Fixed configuration; number of service board slots: 1 |
| Power Modules | 2 modules, 1+1 redundancy |
| Fan Modules | 4 fans, 3 + 1 redundancy |
| Dimensions (H × W × D) | 43.6 mm × 442 mm × 420 mm (1U) |
| Weight (Fully Configured, without packaging) | ~ 9.45 kg |
| Weight (With packaging, full configuration) | ~ 14.45 kg |
| Typical Power Consumption | ~ 336.3 W |
| Heat Dissipation (Typical) | ~ 1091.1 BTU/hour |
| MTBF (Mean Time Between Failures) | ~ 25.65 years |
| MTTR (Mean Time To Repair) | 0.5 hour |
| Power Supply Modes | AC / HVDC |
| Rated Input Voltage | AC: 100-240 V; supports 240 V HVDC |
| Input Voltage Range | AC: 90-290 V |
| Maximum Input Current | ~ 8 A |
| Noise (Normal Temperature, Acoustic Power) | < 72 dB(A) |
| Airflow Direction / Heat Dissipation Mode | Front-to-rear; air cooling |
| Operating Temperature (Long-Term) | 0°C to +45°C |
| Storage Temperature | –40°C to +70°C |
| Operating Humidity (Long-Term) | 5% to 90% RH, non-condensing |
| Short-Term Operating Humidity | 5% to 95% RH, non-condensing |
| Storage Humidity | 5% to 95% RH |
| Operating Altitude | ≤ 4000 m |
| Storage Altitude | < 5000 m |
| Maximum Number of Physical Ports | 56 |
| Max 100GE Ports | 8 |
| Max 50GE Ports | 8 |
| Max 40GE Ports | 8 |
| Max 25GE Ports | 20 |
| Max 10GE Ports | 48 |
| Max GE Ports | 28 |
| Max FE Ports | 28 |
| condition | new |
|---|