Huawei NetEngine 8000E F2C Fixed-configuration router; does not support flexible line cards
Category: Huawei Router
Routers Huawei NetEngine used in individual, private corporate networks of different sizes. The height of the apparatus varies from 2 U to 4 U, And the depth of the units at the same time is everything 220 mm, This feature of switches allows you to significantly save space in the hardware room..
Routers function Huawei NetEngine in a very wide range of temperatures that varies within - 40 up to + 60 degrees, which allows operation in complex, harsh environments.
Technical features:
- Unique chips of their own development Huawei Provide increased information transmission speeds
- «Hard» IP The channel improves the quality of services of a separate IP line
- Unique technologies IP FPM and hardware function BFD allow you to quickly and most importantly determine the fault and its character
- Architecture SDN, Performs a balanced distribution of traffic, increases the efficiency of using the bandwidth
| Specification | Detail |
|---|---|
| Product Name | Huawei NetEngine 8000E F2C |
| Switching Capacity | 14.4 Tbps |
| Forwarding Performance | 1,595 Mpps |
| Maximum Board Capability | Fixed-configuration router; does not support flexible line cards |
| Capacity Density (Gbps per U) | 3,600 Gbps/U |
| Main Control Board | Fixed-configuration |
| SFU (Switch Fabric Unit) Redundancy | Fixed-configuration |
| Line Card / Slot Count | Fixed-configuration; number of service board slots: 1 |
| Power Modules | 2, with 1+1 redundancy |
| Fan Modules | 3, with 2+1 redundancy |
| Dimensions (H × W × D) | 86.1 mm (2U) × 442 mm × 600 mm |
| Weight (without packaging, full configuration) | ~ 23.7 kg (DC version) / ~ 22.9 kg (AC version) |
| Weight (with packaging, full configuration) | ~ 34.2 kg (DC) / ~ 32.1 kg (AC) |
| Typical Power Consumption | ~ 1,226.4 W |
| Heat Dissipation (Typical) | ~ 3,764.3 BTU/hour |
| MTBF | ~ 21.90 years (DC) / ~ 22.03 years (AC) |
| MTTR | 0.5 hour |
| Number of Slots | 6 |
| Number of Service Board Slots | 1 |
| Maximum Number of Physical Ports | 72 |
| Maximum Number of 400GE Ports | 16 |
| Maximum Number of 100GE Ports | 72 |
| Maximum Number of 50GE Ports | 72 |
| Maximum Number of 40GE Ports | 72 |
| Rated Input Voltage | DC: –48 V to –60 V; AC: 100–130 V dual-live-wire / 200–240 V; HVDC: 190–240 V |
| Input Voltage Range | DC: –40 V to –72 V; AC: 90 V to 290 V; HVDC: 190 to 290 V |
| Maximum Input Current | DC: 63 A; AC/HVDC: 16 A |
| Airflow Direction | Front-to-rear airflow model (port-side intake) |
| Operating Temperature (Long-Term) | –5 °C to +45 °C |
| Storage Temperature | –40 °C to +70 °C |
| Operating Humidity (Long-Term) | 5% RH to 90% RH, non-condensing |
| Short-Term Operating Humidity | 5% RH to 95% RH, non-condensing |
| Storage Humidity | 5% RH to 95% RH |
| Operating Altitude | ≤ 4,000 m |
| Storage Altitude | < 5,000 m |
| condition | new |
|---|