Router Huawei NetEngine 8000E M6
SKU
NetEngine 8000E M6
EAN:
21465
Condition:
new
Stock:
available on order
Lead time:
25-35 days
Huawei NetEngine 8000E / 8000 M6 DC model: CR8BM6BKPDC2; AC model: CR8BM6BKPAC2
Category: Huawei Router
Routers Huawei NetEngine used in individual, private corporate networks of different sizes. The height of the apparatus varies from 2 U to 4 U, And the depth of the units at the same time is everything 220 mm, This feature of switches allows you to significantly save space in the hardware room..
Routers function Huawei NetEngine in a very wide range of temperatures that varies within - 40 up to + 60 degrees, which allows operation in complex, harsh environments.
Technical features:
- Unique chips of their own development Huawei Provide increased information transmission speeds
- «Hard» IP The channel improves the quality of services of a separate IP line
- Unique technologies IP FPM and hardware function BFD allow you to quickly and most importantly determine the fault and its character
- Architecture SDN, Performs a balanced distribution of traffic, increases the efficiency of using the bandwidth
| Specification | Detail |
|---|---|
| Product Name | Huawei NetEngine 8000E / 8000 M6 |
| Chassis Part Numbers / Models | DC model: CR8BM6BKPDC2; AC model: CR8BM6BKPAC2 |
| Form Factor / Height (Rack Units) | 2U |
| Dimensions (H × W × D) without packaging | 88.9 mm × 442 mm × 220 mm |
| Dimensions with packaging | 335 mm × 585 mm × 390 mm |
| Weight without packaging (base configuration) | 4.2 kg |
| Weight with full configuration (DC version) | ~ 10.65 kg |
| Weight with full configuration (AC version) | ~ 11.35 kg |
| Switching Capacity | 320 Gbit/s |
| Forwarding Performance | 72 Mpps (million packets per second) |
| Maximum Board Capability | 50 Gbit/s |
| Capacity Density (Gbps per U) | ~ 80 Gbps/U |
| Main Control Board Redundancy | 2 boards, 1:1 redundancy |
| SFU (Switch Fabric Unit) / Integrated SFU | 2 units, 1:1 redundancy; integrated SFU design |
| Number of Service Board Slots | 6 slots (in DC version) / 4 slots (in AC version) |
| Number of Total Slots | 11 |
| Power Supply Modules | 2 modules, 1+1 redundancy |
| Fan Modules | 2 modules, 1+1 redundancy |
| Typical Power Consumption (Typical Configuration, DC) | ~ 196.1 W |
| Typical Power Consumption (Typical Configuration, AC) | ~ 209.7 W |
| Heat Dissipation (Typical, DC) | ~ 285.9 BTU/hour |
| Heat Dissipation (Typical, AC) | ~ 666.3 BTU/hour for some config; alternative ~ 317.4 BTU/h for lighter config |
| Noise Level (at normal temperature) | < 55 dB(A) |
| Operating Temperature (Long-Term) | –40 °C to +65 °C |
| Storage Temperature | –40 °C to +70 °C |
| Operating Humidity (Long-Term) | 5% to 85% RH, non-condensing |
| Short-Term Operating Humidity | 5% to 95% RH, non-condensing |
| Storage Humidity | 5% to 95% RH |
| Operating Altitude | ≤ 4000 meters |
| Storage Altitude | < 5000 meters |
| Power Supply Mode | DC version (−48 V / −60 V) or AC version (200-240 V / 100-127 V, wide range) |
| Maximum Input Current (DC version) | ~ 30 A |
| Maximum Physical Ports (all interface types) | 100 ports |
| Max Number of 10GE Ports | 16 |
| Max Number of GE / FE Ports | Up to 100 depending on configuration |
| condition | new |
|---|