Router Huawei NetEngine 8000E M8

SKU
NetEngine 8000E M8
Call for Price
EAN: 21464
Condition: new
Stock: available on order
Lead time: 25-35 days

Huawei NetEngine 8000E M8 DC Chassis, AC Chassis (various CR8BM8BKP-* versions)

Routers Huawei NetEngine used in individual, private corporate networks of different sizes. The height of the apparatus varies from 2 U to 4 U, And the depth of the units at the same time is everything 220 mm, This feature of switches allows you to significantly save space in the hardware room..

Routers function Huawei NetEngine in a very wide range of temperatures that varies within - 40 up to + 60 degrees, which allows operation in complex, harsh environments.

Technical features:

  • Unique chips of their own development Huawei Provide increased information transmission speeds
  • «Hard» IP The channel improves the quality of services of a separate IP line
  • Unique technologies IP FPM and hardware function BFD allow you to quickly and most importantly determine the fault and its character
  • Architecture SDN, Performs a balanced distribution of traffic, increases the efficiency of using the bandwidth
The characteristics of the router Huawei NetEngine 8000E M8:

Specification Detail
Product Name Huawei NetEngine 8000E M8
Chassis Options / Part Numbers DC Chassis, AC Chassis (various CR8BM8BKP-* versions)
Slot Layout 13 total slots; Service board slots: 8; PIC slots: 8 (DC version) / 6 (AC version)
IPU Redundancy 2 IPUs, 1:1 redundancy
Power Supply 2 modules, 1+1 redundancy; supports AC or DC supply depending on chassis
Dimensions (H × W × D) without packaging 132.6 mm × 442 mm × 220 mm (≈ 3U)
Dimensions with packaging 360 mm × 585 mm × 390 mm
Weight (without packaging, base configuration) ~ 5.7 kg
Weight (packaged base configuration) ~ 9.2 kg
Weight (full configuration, DC version) ~ 16.5 kg
Weight (full configuration, AC version) ~ 17.1 kg
Typical Power Consumption (DC full configuration) ~ 428.11 W
Typical Power Consumption (AC full configuration) ~ 457.79 W
Heat Dissipation (DC version) ~ 1,350.19 BTU/hour
Heat Dissipation (AC version) ~ 1,443.77 BTU/hour
MTBF (Mean Time Between Failures) ~ 155.06 years
MTTR (Mean Time To Repair) 0.5 hour
Availability Very high (carrier-grade)
Noise Level (at normal temperature) < 72 dB(A)
Rated Input Voltage (DC) −48 V / −60 V
Input Voltage Range (DC) −40 V to −72 V
Rated Input Voltage (AC) 200-240 V / 100-127 V dual live wires; supports HVDC in some versions
Input Voltage Range (AC) 90 V to 290 V
Maximum Input Current (DC version) ~ 40 A
Chassis Height (Rack Units) 3U
Airflow / Cooling Mode Air-cooling; airflow direction: left to right
Operating Temperature (Long-Term) −40 °C to +65 °C
Storage Temperature −40 °C to +70 °C
Operating Humidity (Long-Term) 5% to 85% RH (non-condensing)
Short-Term Operating Humidity 5% to 95% RH (non-condensing)
Storage Humidity 5% to 95% RH
Operating Altitude ≤ 4,000 m
Storage Altitude < 5,000 m
Switching / Throughput Capacity ~ 2.4 Tbps
Forwarding Performance (Packets per Second) ~ 453 Mpps
condition new