uawei NetEngine 40E-X8A is a high-capacity service router designed for backbone and high-density network environments. It delivers 51.2 Tbps switching capacity and over 7,200 Mpps forwarding performance in a 21U chassis.
Category: Huawei Router
Routers Huawei NetEngine used in individual, private corporate networks of different sizes. The height of the apparatus varies from 2 U to 4 U, And the depth of the units at the same time is everything 220 mm, This feature of switches allows you to significantly save space in the hardware room..
Routers function Huawei NetEngine in a very wide range of temperatures that varies within - 40 up to + 60 degrees, which allows operation in complex, harsh environments.
Technical features:
- Unique chips of their own development Huawei Provide increased information transmission speeds
- «Hard» IP The channel improves the quality of services of a separate IP line
- Unique technologies IP FPM and hardware function BFD allow you to quickly and most importantly determine the fault and its character
- Architecture SDN, Performs a balanced distribution of traffic, increases the efficiency of using the bandwidth
| Specification | Detail |
|---|---|
| Product Name | Huawei NetEngine 40E-X8A |
| Switching Capacity | 51.2 Tbps |
| Forwarding Performance | 7,232 Mpps |
| MPU Slots | 2 (with 1:1 redundancy) |
| Switch Fabric Units (SFU) Slots | 4 |
| Line Processing / LPU Slots | 8 |
| Chassis Height (Rack Units) | 21 U |
| Dimensions (H × W × D) | 930 mm × 442 mm × 650 mm |
| Weight (Full Configuration) | 186 kg |
| Typical Power Consumption (Full Config, 480G Bundle) | ~ 4,770 W |
| Heat Dissipation (Full Config, 480G Bundle) | ~ 15,476 BTU/hour |
| Power Supply Modes & Redundancy | AC and HVDC / multiple power modules / redundant power supply arrangement varies by bundle |
| MTBF (Mean Time Between Failures) | ~ 22.32 years |
| MTTR (Mean Time To Repair) | ~ 0.5 hour |
| Noise (Acoustic Power, Normal Temp) | NEBS-compliant (< 78 dB(A) @ ~27 °C) |
| Operating Temperature (Long-Term) | 0°C to +45°C |
| Short-Term Operating Temp | –5°C to +55°C |
| Storage Temperature | –40°C to +70°C |
| Operating Humidity (Long-Term) | 5% to 85% RH, non-condensing |
| Short-Term Operating Humidity | 5% to 95% RH, non-condensing |
| Operating Altitude | ≤ 4,000 m |
| Storage Altitude | < 5,000 m |
| condition | new |
|---|