Server Huawei FusionServer 5288 V3 BC1M06HGSE
rack serversВ Huawei FusionServerВ Provide optimal computing power, provide over high capacity of local storage and flexible scaling solutions.
ServersВ Huawei FusionServerВ thanks to innovative technologies, they are ideal units for storing "cold" information, as well as for video surveillance systems, cloud storage and applicationsВ Big Data.
Servers are equipped with ultra-new processorsВ Intel ScalableВ first or second generation. The fully configured hardware processor supports up toВ 28 nucleiВ and uses the busВ Ultra Path Intercorrect, which provides data transfer at a speedВ 10 GT/with.
Increased server scalability with support for up to five expansion slotsВ PCIe 3.0, including one slot forВ RAID-controller. In seriesВ Huawei FusionServerВ supportВ Serial over LAN (SOL), remoteВ KVMВ and remote start and shutdown of devices through an independentВ iBMC.
Server characteristics Huawei FusionServer 5288 V3 BC1M06HGSE:
Number and type of processors supported |
up to two processors IntelВ® Xeon E5-2600 v3/v4 Series (LGA 2011-3/Socket R3, allowable TDP up to 135W) |
Number and type of memory supported |
16 connectors DDR4 DIMM (Registered (RDIMM) or Load Reduced (LRDIMM)) Maximum Memory 512GB 1.2V or 1.02V modules Technology support: В·В В В В В В В В DRAM Single Device Data Correction (SDDCx4) В·В В В В В В В В Memory Disable and Map out for FRB В·В В В В В В В В Data scrambling with command and address В·В В В В В В В В DDR4 Command/Address parity check and retry В·В В В В В В В В Intra-socket memory mirroring В·В В В В В В В В Memory demand and patrol scrubbing В·В В В В В В В В HA and IMC corrupt data containment В·В В В В В В В В Rank level memory sparing В·В В В В В В В В Multi-rank level memory sparing В·В В В В В В В В Failed DIMM isolation |
chipset |
IntelВ® C612 |
IntelВ® QuickPath Technology |
before 9.6 GT/s |
disk subsystem |
Depending on server modification: В·В В В В В В В В up to twenty-four drives LFF (3'5) hot swappable with front panel access В·В В В В В В В В up to twenty-four drives LFF (3'5) hot-swap front-accessible + up to twelve rear-accessible drives Ability to install four drives LFF (3'5/2'5) no hot swap support |
Network interface controllers |
Depending on server modification: В·В В В В В В В В two ports 1G (support NCSI, Wake on LAN (WOL), and Preboot Execution Environment (PXE)) В·В В В В В В В В Four ports 1G (support NCSI, WOL, PXE) В·В В В В В В В В Two 10G optical ports (support NCSI and PXE) В·В В В В В В В В Two 10G copper ports (support NCSI, WOL, PXE) |
Disk array controllers |
Possibility to install various variants of disk array controllers with support for levels RAID (0, 1, 10, 1E, 5, 50, 6 and 60), variable cache size (from 0MB before 2GB) and support for batteryless protection modules. |
I/O ports |
two ports USB 2.0 (front panel) |
Remote control |
Onboard controller В BMC c support IPMI 2.0 built-in 2DВ Video 16MB DDR3 Dedicated 1000T Ethernet management port and function KVM-over-IP Embedded WEB server KVM-over-IP |
Cooling system |
Four dual fans with separate control (80mm) connected according to the scheme N+1 One fan in every power supply |
Expansion slots |
Three slots PCIe 3.0 x8 Dedicated slot PCIe 3.0 x8 for installation RAID controller Support for full size cards. |
power unit |
Up to two hot-swappable power supplies DC power supplies (-48V):800W Support for operating modes : 1+0, 1+1 (failover mode), 2+0 (toMbionized mode) |
Rack Mount Kit |
included |
form factor |
4U |
Physical dimensions |
175 mm x 447 mm x 748 mm |
Ambient operating temperature |
from +5 to +45 C, with a temperature change of no more than 20 C per hour |
Storage Options |
Temperature :from -40 to +70 C Humidity: 50% to 90% non-condensing. |
Power options |
Voltage : from 180 to 234V Frequency: 47 to 63 Hz The loss of external voltage is allowed for no more than 12 mSec |
Warranty |
Three years warranty Various service options available at an additional cost |
В
В
condition | new |
---|
Log In