HPE FlexFabric 5944 series (JL836A)
|
I/O ports and slots
|
48 x 1/10GBASE-T ports
|
6 x QSFP28 100GbE ports
|
Additional ports and slots
|
1 x console port
1 x mini USB port
1 x USB port
2 x out-of-band management ports (1 x SFP GbE port and one copper port)
|
Power supplies
|
2 power supply slots
1 minimum power supply required (ordered separately)
|
Fan tray
|
5 fan tray slots
5 hot-swappable fans, fan speed adjustable with reversible airflow.
Note: The customer must order fan trays, as they are not included with the switch. The system should not be operated with less than five fan trays for more than 24 hours. The system should not be operated without a fan tray for more than two minutes. The system should not be operated outside of the temperature range of 32°F (0°C) to 113°F (45°C). Failure to comply with these operating requirements may void the product warranty.
|
Physical characteristics
|
Dimensions
|
18.11 in. (w) x 17.32 in. (d) x 1.73 in. (h) (46 cm x 44 cm x 4.4 cm) (1U height)
|
Weight
|
22.05 lb (< 10 kg)
|
Memory and processor
|
4 GB flash; packet buffer size: 32 MB, 8 GB SDRAM
|
Mounting and enclosure
|
Mounts in an EIA standard 19-inch telco rack or equipment cabinet (hardware included)
|
Performance
|
Latency
|
< 1 µs (64-byte packets)
|
Throughput
|
1001.7 Mpps
|
Routing/switching capacity
|
2.16 Tbps
|
Routing table size
|
324K entries (IPv4), 162K entries (IPv6)
|
MAC address table size
|
288K entries (max.)
|
Environment
|
Operating temperature
|
32°F to 113°F (0°C to 45°C)
|
Operating relative humidity
|
10% to 95%, noncondensing
|
Acoustic
|
Low-speed fan: 67 dB, high-speed fan: 71 dB
|
Electrical characteristics
|
Frequency
|
50/60 Hz
|
Maximum heat dissipation
|
887 BTU/hr (935.79 kJ/hr)
|
Voltage
|
100 - 240 VAC, rated
|
DC voltage
|
–40 VDC to –60 VDC rated
|
Maximum power rating
|
233W
|
Idle power
|
102W
|
Notes:
|
- Idle power is the actual power consumption of the device with no ports connected.
- Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
|
Safety
|
UL 60950-1, CAN/CSA-C22.2 No. 60950-1, IEC 60950-1, EN 60950-1, AS/NZS 60950.1, FDA 21 CFR Subchapter J
|
Emissions
|
FCC Part 15 (CFR 47) Class A, ICES-003 Class A, VCCI Class A, CISPR 32 Class A, EN 55032 Class A, AS/NZS CISPR 32 Class A, EN 61000-3-2, EN 61000-3-3, ETSI EN 300 386
|
Immunity
|
CISPR 24, EN 55024, ETSI EN 300 386
|
Management
|
IHPE IMC; CLI; out-of-band management; SNMP manager; Telnet; FTP
Note: The customer must install a minimum of one power supply, as the device does not come with one. The customer must install five fan kits, as the device does not come with one.
|