Model
|
CloudEngine S5735-S8P2X-IA200G1
|
Fixed port
|
8 x 10/100/1000Base-T ports and 2 x 10G SFP+ ports
|
Management port
|
Ethernet management port, console port (RJ45), and USB 2.0 port
|
PoE
|
• 8 PoE+ ports, each providing up to 30 W power
• 802.3af/802.3at standards compliance
• Maximum total PoE output power: 160 W
|
Dimensions (H x W x D)
|
550 mm x 300 mm x 135 mm
|
Net weight
|
9.2kg
|
Rated voltage range
|
220 V AC to 240 V AC, 50/60 Hz
|
Maximum voltage range
|
176 V AC to 264 V AC, 45 Hz to 66 Hz
|
Maximum power consumption (100% throughput)
|
• No power output: 34 W
• 100% power output: 209 W (system power consumption: 49 W; power output: 160 W)
|
Typical power consumption (30% of traffic load, without PoE power output)
|
31 W
|
Power output
|
• Maximum total output power of 12 V DC + 24 V AC + PoE: 160 W
• 12 V DC (five outputs): 72 W in total, with a maximum of 72 W for each output
• 24 V AC (two outputs): 72 W in total, with a maximum of 72 W for each output
• Eight PoE ports provide a maximum of 160 W power
• 220 V AC (Optional)
|
Fiber splice tray
|
Built-in(Optional)
|
Protection rating
|
IP55
|
Operating temperature
|
-40℃ to +75℃
NOTE
–25ºC to +75ºC : sunshade needed; 400 LFM air velocity (minimum); GPON optical modules not supported
–25ºC to +70ºC : sunshade needed; 200 LFM air velocity (minimum); GPON optical modules supported
–30ºC to +60ºC : sunshade needed; 40 LFM air velocity (minimum); GPON optical modules supported
–35ºC to +55ºC : sunshade needed; no requirement on the air velocity; GPON optical modules supported
–35ºC to +45ºC : 1120 W/m2 solar radiation (maximum); no requirement on the air velocity
–40ºC to –35ºC : At least four Ethernet electrical ports must be working. When the altitude is 1800-4000 m , the highest operating temperature reduces by 1°C every time the altitude increases by 220 m.
|
Power supply surge protection
|
Surge current:
• AC input: 20 kA
Surge:
• AC input: ±6 kV in differential mode; ±6 kV in common mode
• 12 V DC output: ±2 kV in differential mode; ±4 kV in common mode
• 24 V AC output: ±2 kV in differential mode; ±6 kV in common mode
|
Service port surge protection
|
±1.5 kV in differential mode, ±6 kV in common mode
|
Salt spray protection
|
Supported, allowing the switch to be installed in areas more than 500 meters away from the sea
|
Operating altitude
|
0-4000 m
|
Heat dissipation
|
Natural heat dissipation
|
Installation mode
|
Wall-mounted or pole-mounted
|