Switch Huawei CloudEngine S5735I-S8T4XN-T-V2
Huawei CloudEngine S5735I-S8T4XN-T-V2 8 × 10/100/1000Base-T downlink ports; 4 × 10GE SFP+ uplink ports
Huawei S5700 – A series of highly effective, innovative switches consisting of a large number of devices and with different numbers 1G ports. Switches are equipped with interfaces uplink 10G and the enormous functionality of the software (Software).
Switches Huawei S5700 intended for use in places where excellent, high throughput, minimal latency, and fault tolerance are required.
Depending on the functionality of the software switches series Huawei S5700 separated into several series.
The switches are based Huawei — Versatile Routing Platform (VRP).
The peculiarity of this series of switches is: improved functionality 3-The level, Simplified operation and maintenance and flexible ways to organize the Internet.
Specifications of the switch Huawei CloudEngine S5735I-S8T4XN-T-V2:
| Specification | Detail |
|---|---|
| Product Name / Model | Huawei CloudEngine S5735I-S8T4XN-T-V2 |
| Port Configuration | 8 × 10/100/1000Base-T downlink ports; 4 × 10GE SFP+ uplink ports |
| Alarm / Management Ports | 1 × DI (alarm input); 1 × DO (alarm output); 1 × RS-485 console port |
| Switching Capacity | 96 Gbps |
| Forwarding Performance | 72 Mpps |
| Memory | 2 GB |
| Flash Memory | 1 GB |
| Power Supply Type | External DC or AC power adapter, 1+1 hot-backup |
| Rated Input Voltage | DC input: 12 V to 48 V |
| Input Voltage Range (Max) | DC input: 9.6 V to 60 V |
| Typical Power Consumption | ~19.94 W (under ~30% traffic load) |
| Maximum Power Consumption | ~20.35 W |
| Dimensions (without packaging) | 150.0 × 86.0 × 133.0 mm |
| Dimensions (with packaging) | 162.0 × 86.0 × 142.0 mm |
| Weight (with packaging) | ~2.11 kg |
| Operating Temperature (altitude 0-1800m, with industrial optical modules) | -40 °C to +65 °C (sealed cabinet) • -40 °C to +70 °C (ventilated cabinet, ≥ 80 LFM airflow) • -40 °C to +75 °C (ventilated cabinet with blower, ≥ 200 LFM airflow) |
| Storage Temperature | -40 °C to +85 °C |
| Relative Humidity (Operating / Storage) | 5% to 95% RH, non-condensing |
| Operating Altitude | 0 to 5000 m |
| Enclosure / Design | Metal chassis; fanless; natural heat dissipation; DIN-rail mountable; IP40 ingress protection |
| Surge Protection | Service ports: ±7 kV common-mode; power supply: ±2 kV differential mode & ±1 kV common mode |
| Standards / Reliability | High availability (no fans, redundancy in power supply), long MTBF, industrial-grade robustness |
| condition | new |
|---|