Model
|
CloudEngine S5735IS8U4XN-V2
|
Fixed port
|
8 x 10/100/1000BASE-T ports, 4 x 10GE SFP+ ports
|
Console port
|
1 x RS485
|
Alarm port
|
1 x DI (Monitoring alarm input port), 1 x DO (Shorts and Opens alarm output port)
|
Dimensions (H x W x D)
|
150.0 mm x 86.0 mm x 133.0 mm
|
Mounting
|
DIN rail
|
Weight (with packaging)
|
2.21kg
|
IP level
|
IP40
|
Power supply type
|
240W AC (AC PoE power adapter) or DC external
|
Rated voltage range
|
DC input: 56V DC
|
Maximum voltage range
|
DC input: 54V DC~57V DC
|
Maximum power consumption
|
• 21.7 W (without PD)
• 421.7 W (with PD, PD power consumption of 400 W)
|
Typical power consumption (30% of traffic load)
|
20.45 W
|
Operating temperature
|
0–1800 m altitude, industry optical modules:
• -40°C to +60°C (installed in the sealing cabinet)
• -40°C to +70°C (installed in the ventilation cabinet, with the wind speed of at least 80 LFM)
• -40°C to +75°C (installed in the ventilation cabinet shipped with fans running at a speed of at least 200 LFM)
|
Storage temperature
|
NA
|
Ingress protection level
|
IP40
|
Power supply surge protection
|
Using DC power modules: ±2 kV in differential mode, ±1 kV in common mode
|
Service port surge protection
|
Common mode: ±7 kV
|
Noise under normal temperature (27°C, sound power)
|
Noise-free (no fans), < 30 dB(A)
|
Relative humidity
|
5% to 95%, noncondensing
|
Heat dissipation
|
Natural heat dissipation
|